SERVICE PROGRAM MODE TABLES
20 June 2005
5-54
5836 94 Default Format for Backup
Files
Sets the format of the backup files.
[0~2/1]
0: TIFF
1: JPEG
2: For printing
This feature can be selected only if SP5836-3 is set to
“1”.
5836 95 Default Resolution for
Backup Files
Sets the resolution conversion ratio for the backup files.
[0~3/1]
0: 1x
1: 1/2x
2: 1/3 x
3: 1/4x
5836 97 Default Compression for
Backup Files
Sets the rate of compression for the backup files.
[0~2/1]
0: Standard
1: Low
2: High
5836 98 Back Projection Removal
Removes the ghost images that are copied from the
back sides of two-sided originals.
[0~1/1]
0: Disable
1: Enable
IEEE 1394
5839
This SP is displayed only when an IEEE 1394 (firewire) card is installed.
Host Name
5839 4
Enter the name of the device used on the network. Example: RNP0000000000
Cycle Master
5839 7
Enables or disables the cycle master function for the 1394 bus standard.
[0~1/1]
0: Disable (Off)
1: Enable (On)
BCR Mode
5839 8
Determines how BCR (Broadcast Channel Register) operates on the 1394 standard
bus when the independent node is in any mode other than IRM. (NVRAM: 2-bits)
[Always Effective]
IRM 1394a Check
5839 9
Conducts a 1394a check of IRM when the independent node is in any mode other
than IRM.
[0~1/1]
0: Checks whether IRM conforms to 1394a
1: After IRM is checked, if IRM does not conform then independent node switches to
IRM.
Unique ID
5839 10
Lists the ID (Node_Unique_ID) assigned to the device by the system administrator.
Bit0: Off
Bit1: On
OFF: Does not list the Node_Unique_ID assigned by the system administrator.
Instead, the Source_ID of the GASP header in the ARP is used.
ON: The Node_Unique_ID assigned by the system administrator is used, and the
Source_ID of the GASP header in the ARP is ignored. Also, when the serial
bus is reset, extra bus transactions are opened for the enumeration.