20 June 2005
PHOTOCONDUCTOR UNIT (PCU)
3-33
Replacement
Adjustment
3.11.3 PICK-OFF PAWLS
1. Remove the drum. (
3.11.2)
2. Pawl assembly [A]
3. Pick-off pawl [B] (spring x 1, spur x 1)
Pick-off pawl position adjustment
If the pick-off pawl has marked the drum with a line, the pick-off pawl position can
be adjusted using either method:
•
Changing the spur position.
•
Changing the pick-off pawl assembly position
CAUTION:
After re-assembly make sure that the front spring of the movable
cleaning blade is re-attached to the
,
position. ( 3.11.2)
B195R933.WMF
[A]
[B]