MAIN MACHINE INSTALLATION
20 June 2005
1-16
Initialize TD Sensor and Developer
1. Connect the main machine to the power outlet, switch on the main machine,
and wait for the fusing unit to warm up.
2. On the operation panel, press Clear Mode
.
3. Use the number keys to enter 107.
4. Press and hold Clear/Stop
for three seconds.
5. On the touch-panel, press Copy SP.
6. Press SP Direct to highlight “SP Direct”, enter 2801, and then press
.
7. When the message prompts you to enter the lot number of the developer, enter
the 7-digit lot number, press [Yes], and then press [Execute] on the touch-
panel. This initializes the TD sensor.
NOTE:
The lot number is printed on the end of the developer package.
Recording the lot number could help troubleshoot problems later. If the
lot number is unavailable, enter any seven-digit number.
8. Press SP Direct to highlight “SP Direct” and enter 2805, press
, and then
press Execute on the touch-panel. This initializes the developer.
9. Press Exit twice to return to the copy window.