SERVICE PROGRAM MODE TABLES
20 June 2005
5-128
5.2.9 MEMORY CLEAR: SP5-801
Executing Memory All Clear resets all the settings stored in the NVRAM to their
default settings except the following:
SP7-003-1: Electrical
total counter value
SP5-811-1:
Machine serial number
SP5-907:
Plug & Play Brand Name and Production Name Setting
1. Execute SP5-990 to print out all SMC Data Lists.
2. Open SP mode 5-801.
3. Press the number for the item that you want to initialize. The number you select
determines which application is initialized. For example, press 1 if you want to
initialize all modules or select the appropriate number from the table below.
5801
Memory Clear
Comments
5801 1
All Clear
Initializes items 2 ~ 12 below.
*1
5801 2
Engine
Initializes all registration settings for the engine
and processing settings.
*1
5801 3
SCS
Initializes default system settings, CSS settings,
operation display coordinates, and ROM update
information.
*1
5801 4
IMH Memory Clr
Initializes the registration setting for the image
memory handler by deleting all image files on
the HDD.
5801 5
MCS
Initializes the automatic delete time setting for
stored documents.
5801 6
Copier application
Initializes all copier application settings.
5801 7
Fax application
Initializes the fax reset time, job login ID, all
TX/RX settings, local storage file numbers, and
off-hook timer.
5801 8
Printer application
Initializes the printer defaults, programs
registered, the printer SP Bit SW, and printer
CSS counter.
5801 9
Scanner application Initializes the scanner defaults for the scanner
and all the Scanner SP modes.
5801 10
Web
Service/Network
Application
Deletes the NFA management files and
thumbnails, and initializes the JOB login ID.
5801 11
NCS
Initializes the system defaults and interface
settings (IP addresses also), the
SmartNetMonitor for Admin, WebStatusMonitor
settings, and the TELNET settings.
5801 12
R-FAX
Initializes the Job login ID, SmartNetMonitor for
Admin, Job History, and local storage file
numbers.
5801 13
Clear DCS Settings
Initialization
5801 14
Clear UCS Settings
Initialization
1*
:
Resetting 1~3 resets the operation panel screen coordinates, so after executing 1, 2, or 3,
you must re-calibrate the screen.