Administrator’s Section
47
Relocking refers to the ability to dimension a new object even in cases when no ready state was detected due to
particularly fast operations.
5.4.3
Restore Configuration Button
Use
to restore the settings on this page to their default values or to restore from a previously
saved backup file.
Motion Up (%)
A low-pass filter is applied to the motion detected from every single frame that is
captured. These two parameters (up and down) control the speed of this low-pass
filter as a percentage. The closer to 100%, the faster the filter’s response; the closer
to 0%, the slower the filter’s response.
Default Value: 90%
Valid Values: 0-100%
Motion Down (%)
Default Value: 50%
Valid Values: 0-100%
Lock Rect Score (%)
Specifies a minimum tracking confidence value that needs to be reached in order to
trigger the capture of the object’s dimensions.
Default Value: 0%
Valid Values: 0-100%
Weight Diff Ready (%)
When an object is removed from the scale, the reported weight will obviously drop.
This parameter determines the percentage of weight drop necessary to reset the
system to a ready state. This percentage is relative to the weight of the object that
was last dimensioned.
Default Value: 50%
Valid Values: 0-100%
Min Weight Ready (%)
The weight threshold value (in grams) below which the system will determine that
there is not an object on the scale and will switch to a ready state.
Default Value: 100 g
Valid Values: 0-200 g
Parameters
Description
Values
Diff Center Enabled
Determines whether or not the system should relock based on the detection of
a shift in the object’s center.
Default Value: Off
Valid Values: On/Off
Diff Center (mm)
Specifies the amount of variation in the location of the object placed on the
platform which will trigger the capture of new dimensions.
Default Values: 100 mm
Valid Values: 20 - 300 mm
Diff Theta Enabled
Determines whether or not the system should relock based on the detection of
a shift in the object’s orientation.
Default Value: 0.262
Valid Values: 0.1-0.4
Diff Theta (rad)
Specifies the amount of variation in the orientation of the object placed on the
platform which will trigger the capture of new dimensions.
Default Value: 0.262
Valid Values: 0.1- 0.4
Diff Dim Enabled
Determines whether or not the system should relock based on inconsistencies
in the reported dimensions for the object.
Default Value: Off
Valid Values: On/Off
Diff Dim (mm)
Specifies the amount of variation in the dimensions of consecutive objects
placed on the platform which will trigger the capture of new dimensions.
Default Value: 50 mm
Valid Values: 20 - 100 mm
Diff Weight Enabled
Determines whether or not the system should relock based on inconsistencies
in the reported weight for the object.
Default Value: Off
Valid Values: On/Off
Diff Weight (%)
Specifies the amount of variation in the weight received from the scale which
will trigger the capture of new dimensions. The threshold weight value (weight
percentage) determines which inconsistencies should be detected in order to
trigger a relock.
Default Value: 10%
Valid Values: 0-100%
Table 5-20. Relocking
Parameters
Description
Values
Table 5-19. Locking
Summary of Contents for IDIMENSION 200
Page 2: ...iDimension 300 Industrial Installation Manual PN 169040...
Page 3: ......
Page 15: ...12 iDimension 300 6 Click Done to save the settings...
Page 35: ...32 iDimension 300 General Settings Figure 5 10 iDimension 300 General Settings Main Menu...
Page 69: ...66 iDimension 300...
Page 70: ...Administrator s Section 67...
Page 71: ......