General Settings Tab
Scale Type
Scale type is selectable from a drop-down list. If a preferred scale is not listed below, contact Rice Lake Weighing
Systems Customer Support for assistance.
Parameter
Definition
Values
High Resolution
Camera
Determines whether or not a high resolution image of the object should be cap-
tured when it is dimensioned. High Resolution Image Capture is controlled by the
Capture Definitions (see “Capture Definitions” on page 26). This switch can be
used to turn off the high resolution camera, completely overriding any capture
definitions. This may provide some performance improvements for customers that
do not need images from the high resolution camera.
Default Value: On
Valid Values: On/Off
Auto Trigger
Flats
Determines whether the capture of dimensions, weight and image is automatically
triggered for items classified as “Flats.” Flats are represented by items with a
height up to the value specified by the Flat/Parcel Threshold. When switched on,
the capture process will be initiated as soon as a flat item is placed on the Work
Area (see “Zone of Interest” on page 21) and the item is stable (a stable weight
has been received from a connected scale).
Default Value: On
Valid Values: On/Off
Auto Trigger
Parcels
Determines whether the capture of dimensions, weight and image is automatically
triggered for items classified as ‘Parcels.’ Parcels are items with a height greater
than the value specified by the “Flat/Parcel Threshold.” When switched on, the
capture process will be initiated as soon as a Flat item is placed on the work area
(see “Zone of Interest” on page 21), the item is stable (a stable weight has been
received from a connected scale) and if scale is present, the scale weight has
been settled.
Default Value: On
Valid Values: On/Off
Flat Detection
Determines whether the system will process or ignore items classified as flats. If it
is set to ‘Off,’ it will override ‘Auto Trigger Flats’ and any capture definitions.
Default Value: Off
Valid Values: On/Off
Irregular Shape
Object
Determines whether the system will process or ignore items classified as
Irregular
Shapes
. If set to
Off
, irregular shaped objects will be ignored (nothing will be
returned).
Default Value: Off
Valid Values: On/Off
Flat/Parcel
Threshold
The maximum height (in millimeters) of what should be considered a flat object.
Default Value: 30 mm
Valid Values:
30 mm-50 mm
Self Recovery
The desired behavior in the event of a critical error. Restarting will restart the
service that is running on the device. Reboot will reboot the full operating system
on the device.
Default Value: Off
Valid Values: Restart/Reboot
Table 5-2. General Settings Tab
Scale Type
Description
Auto
Will attempt to identify the scale and, if identified, will use that scale. Auto is the default value.
None
There is no scale attached. Flats are not supported in this model.
External
There is no scale attached and the application must trigger from either a bar code scan or by using the
ScaleService API to notify
iDimension
of a change in weight.
USBHID
A scale which uses the USBHID protocol is connected.
Mettler Toledo
A scale which uses the Mettler Toledo standard protocol is connected.
MTSICS
A scale which uses the MTSICS (Mettler Toledo Standard Interface Command Set) protocol is connected.
NCI
A scale which uses the Weigh Tronix/NCI protocol is connected.
Penssylvania7300
The Pennsylvania 7300 scale is connected.
Table 5-3. Scale Type
Summary of Contents for IDIMENSION 200
Page 2: ...iDimension 300 Industrial Installation Manual PN 169040...
Page 3: ......
Page 15: ...12 iDimension 300 6 Click Done to save the settings...
Page 35: ...32 iDimension 300 General Settings Figure 5 10 iDimension 300 General Settings Main Menu...
Page 69: ...66 iDimension 300...
Page 70: ...Administrator s Section 67...
Page 71: ......