Long Term Storage
Audit Trail Retention specifies the number of days captured data will be retained in Long Term Storage.
Default Value: 0.
Parameters
Description
Values
Factory Focal Length
(pixels)
Focal length of the depth sensor for the purpose of factory calibration, pro-
vided in pixels relative to its resolution.
Default Value: 285
Valid Values: N/A
Use Default
Focal Length (pixels)
Focal length of the depth sensor, provided in pixels relative to its resolution.
Default Value: 285
Depth Min (mm)
Threshold Depth Value - the minimum distance allowed (in millimeters)
between the device head and the object it is measuring. Any depth measure
returned by the sensor that is below this value will be ignored.
Default Value: 700
Valid Values: 600-1800
(or “Depth max” value)
Depth Max (mm)
Threshold depth value (in millimeters) above which any depth measure
returned by the sensor will be ignored.
Default Value: 1800
Valid Values: 600 (or
“Depth min value”) to
1800
Depth Camera Height
(mm)
Distance (in millimeters) between the depth sensor and the base of the
device.
Default Value: 1530
Valid Values: 600-1800
Parallax
This is a read-only field.
Correction factor compensating for slight parallax imperfections.
Table 5-15. Depth Sensor
Parameters
Description
Values
Factory Focal Length
(pixels)
Initial focal length of the low-resolution camera for the purpose of factory
calibration (in pixels) relative to its resolution.
Default Value: 269
Valid Values: N/A
Use Default.
Focal Length (pixels)
Focal length of the low resolution camera, provided (in pixels) relative to
its resolution.
Default Value: 269
Valid Values:
Use default value unless
directed to change by
Rice Lake Customer
Support
Table 5-16. Low Resolution Cameras
Parameters
Description
Values
Raw Dimension
Instructs the system to return raw results that have not been rounded to
the nearest division.
Default Value: Off
Valid Values: On/Off
Table 5-17. Results
Parameters
Description
Values
Warmup Threshold
(mins)
Specifies the number of minutes after a cold start that the system will wait
before entering a READY state or before calibration is allowed.
Default Value: 180
Valid Values: 0 or higher
(max int)
Summary of Contents for IDIMENSION 200
Page 2: ...iDimension 300 Industrial Installation Manual PN 169040...
Page 3: ......
Page 15: ...12 iDimension 300 6 Click Done to save the settings...
Page 35: ...32 iDimension 300 General Settings Figure 5 10 iDimension 300 General Settings Main Menu...
Page 69: ...66 iDimension 300...
Page 70: ...Administrator s Section 67...
Page 71: ......