![Rice Lake IDIMENSION 200 Installation Manual Download Page 17](http://html1.mh-extra.com/html/rice-lake/idimension-200/idimension-200_installation-manual_1453986017.webp)
14
iDimension 300
5. Click
Save
when done.
iDimension 300
will automatically restart to apply the changes.
Figure 3-3. Scale Type and Scale Comm Parameters
Scale Type
Scale type is selectable from a drop-down list. If the scale is not listed below, contact Rice Lake Weighing Systems
for assistance.
Scale Communication Parameters
Any required parameters needed to control communication with the scale can be entered into this field.
For serial scale connections (namely Mettler Toledo, MTSICS, NCI and Pennsylvania 7300), other than the default
values (which can be left empty), the following format is expected:
<BAUD RATE>,<PARITY>,<BITS>,<STOPBITS>
Eg. 9600,N,8,1
Table 3-2. Valid Values for Scale Communication Parameters
For USBHID, other than the supported scales listed, the scale communication parameters should contain the
vendor and product ID in the following format:
<VENDOR ID>,<PRODUCT ID>
Scale Type
Description
Auto
iDimension 300
will attempt to identify the scale and, if identified, will use that scale.
None
There is no scale attached to the
iDimension 300
.
External
There is no scale attached to
iDimension 300
and the application must trigger
iDimension 300
from either a bar code scan or by using the ScaleService API to notify
iDimension 300
of a
change in weight.
USBHID
A scale which uses the USBHID protocol is connected to
iDimension 300
.
Mettler Toledo
®
A scale which uses the Mettler Toledo standard protocol is connected to the
iDimension 300
.
MTSICS
A scale which uses the MTSICS (Mettler Toledo Standard Interface Command Set) protocol is
connected to
iDimension 300
.
NCI
A scale which uses the Weigh Tronix/NCI protocol is connected to
iDimension 300
.
Pennsylvania
®
7300 The Pennsylvania 7300 scale is connected to
iDimension 300
.
Table 3-1. Scale Types
Parameters
Values
Baud Rate
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600 and 115200
Parity
N,O,E
Bits
5,6,7,8,9
Stopbits
1,1.4,2
Summary of Contents for IDIMENSION 200
Page 2: ...iDimension 300 Industrial Installation Manual PN 169040...
Page 3: ......
Page 15: ...12 iDimension 300 6 Click Done to save the settings...
Page 35: ...32 iDimension 300 General Settings Figure 5 10 iDimension 300 General Settings Main Menu...
Page 69: ...66 iDimension 300...
Page 70: ...Administrator s Section 67...
Page 71: ......