Section 10
Direct Memory Access Controller (DMAC)
Rev. 0.50 May 18, 2006 Page 397 of 1588
REJ09B0313-0050
10.3.9
DMA Extension Resource Selectors 0 to 3 (DMARS0 to DMARS3)
The DMA extension resource selectors (DMARS) are 16-bit readable/writable registers that
specify the source of the DMA transfer request from peripheral modules in each channel.
DMARS0 is for channels 0 and 1, DMARS1 is for channels 2 and 3, DMARS2 is for channels 4
and 5, and DMARS3 is for channels 6 and 7. Table 10.4 shows the specifiable combinations.
DMARS can specify the following transfer request sources: eight SCIF sources, eight IIC3
sources, one A/D converter source, five MTU2 sources, and two CMT sources, two USB sources,
two FLCTL sources, four SSI sources, and four SSU sources.
Two RCAN-TL sources do not need to be specified by these registers, for these two sources can
be specified using the RS3 to RS0 bits in the DMA channel control register (CHCR).
•
DMARS0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Bit:
Initial value:
R/W:
CH1 MID[5:0]
CH1 RID[1:0]
CH0 RID[1:0]
CH0 MID[5:0]
•
DMARS1
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Bit:
Initial value:
R/W:
CH3 MID[5:0]
CH3 RID[1:0]
CH2 RID[1:0]
CH2 MID[5:0]
•
DMARS2
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Bit:
Initial value:
R/W:
CH5 MID[5:0]
CH5 RID[1:0]
CH4 RID[1:0]
CH4 MID[5:0]
•
DMARS3
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Bit:
Initial value:
R/W:
CH7 MID[5:0]
CH7 RID[1:0]
CH6 RID[1:0]
CH6 MID[5:0]
Summary of Contents for Single-Chip Microcomputer SH7203
Page 2: ...Rev 0 50 May 18 2006 Page ii of xxx ...
Page 30: ...Rev 0 50 May 18 2006 Page xxx of xxx ...
Page 52: ...Section 1 Overview Rev 0 50 May 18 2006 Page 22 of 1588 REJ09B0313 0050 ...
Page 98: ...Section 2 CPU Rev 0 50 May 18 2006 Page 68 of 1588 REJ09B0313 0050 ...
Page 128: ...Section 4 Clock Pulse Generator CPG Rev 0 50 May 18 2006 Page 98 of 1588 REJ09B0313 0050 ...
Page 200: ...Section 6 Interrupt Controller INTC Rev 0 50 May 18 2006 Page 170 of 1588 REJ09B0313 0050 ...
Page 242: ...Section 8 Cache Rev 0 50 May 18 2006 Page 212 of 1588 REJ09B0313 0050 ...
Page 400: ...Section 9 Bus State Controller BSC Rev 0 50 May 18 2006 Page 370 of 1588 REJ09B0313 0050 ...
Page 696: ...Section 13 Watchdog Timer WDT Rev 0 50 May 18 2006 Page 666 of 1588 REJ09B0313 0050 ...
Page 726: ...Section 14 Realtime Clock RTC Rev 0 50 May 18 2006 Page 696 of 1588 REJ09B0313 0050 ...
Page 876: ...Section 17 I2 C Bus Interface 3 IIC3 Rev 0 50 May 18 2006 Page 846 of 1588 REJ09B0313 0050 ...
Page 1054: ...Section 21 D A Converter DAC Rev 0 50 May 18 2006 Page 1024 of 1588 REJ09B0313 0050 ...
Page 1294: ...Section 24 LCD Controller LCDC Rev 0 50 May 18 2006 Page 1264 of 1588 REJ09B0313 0050 ...
Page 1386: ...Section 26 I O Ports Rev 0 50 May 18 2006 Page 1356 of 1588 REJ09B0313 0050 ...
Page 1512: ...Section 30 List of Registers Rev 0 50 May 18 2006 Page 1482 of 1588 REJ09B0313 0050 ...
Page 1598: ...Section 31 Electrical Characteristics Rev 0 50 May 18 2006 Page 1568 of 1588 REJ09B0313 0050 ...
Page 1606: ...Appendix Rev 0 50 May 18 2006 Page 1576 of 1588 REJ09B0313 0050 ...
Page 1618: ...Rev 0 50 May 18 2006 Page 1588 of 1588 REJ09B0313 0050 ...
Page 1621: ......
Page 1622: ...SH7203 Group Hardware Manual ...