10.
Route 1" Radiator Hose between left side Radiator Inlet and Expansion
Bottle on top of engine. Insert Hose Spring into Radiator Hose until
located at bend area to help prevent possible hose collapse. Fabricate
Anti-chafe for the Radiator Hose by splitting a leftover piece and securing
around the Hose with Plastic Ties.
11.
Secure all hoses with Hose Clamps.
12.
Rivet Coolant Recovery Bottle Mount Bracket with Spacer Shims to
firewall. Secure Overflow Bottle with supplied Clamp to the Mount Bracket.
13.
Route Overflow Hose from Coolant Bottle to Expansion Bottle on engine.
Secure Overflow Hose at each end with Safety Wire.
RADIATOR DUCT INSTALLATION
14.
Rivet FWD and AFT Inlet Ducts together per parts manual.
15.
Cut Trimlock to length to fit AFT flanges of Duct Assembly and press into
place.
16.
Position Duct Assembly under Engine Mount and secure with Cushion
Clamps to Engine Mount tubes.
NOTE: AFT edge of Trimlock should seal
against Radiator.
Mounting holes in Duct Assembly may be slotted slightly
to allow positioning for a better seal against Radiator.
17.
Cut Trimlock to length to fit lower flanges of Duct Assembly. Press into
place. Lower Cowling will seal against Trimlock.
OPTIONAL HEATER INSTALLATION - RADIANT STYLE
NOTE:
Heater Installation will require the curved Coolant Tube to be removed
from the standard Coolant System and be replaced with other
components. Refer to Parts Pages.
18.
Drill two 1 1/8" holes in the left hand side of the firewall. Locate holes to
avoid Firewall Components and Exhaust System. Cut Serrated Grommet
Strip to length and install to inside of holes as anti-chafe.