![background image](http://html1.mh-extra.com/html/ranko/r55/r55_maintenance-manual_3658497009.webp)
Oil-water separation indication light (for forklift with imported
engine)
While the engine is working, this indicating light will be on when the
precipitation of the water is to a certain degree. Under normal condition,
this indicating light will be on when the start switch is placed in "ON" , and
it will go out after the engine is started. Attention: if the light keeps on or
twinkling while the engine is working, please immediately shut down the
machine to drain the water.
Pre-heat indicating light
Put the key switch in "OFF" and contra-rotate and wait the light to be
on for a short while (the key will automatically return to the "OFF" place
when you loose the hand). When the light goes out, you can put the switch
in "START" position to start the machine.
Oil temperature alarm light (for fluid-control Forklift)
It warns the temperature of fluid drive oil and will be on or twinkling
when the temperature of drive oil reaches
4
3
0
°
F
. You must immediately
stop operation and reduce the engine speed to cool down till the alarm
light goes out.
Right turning indicating light
When the right turning light is on, then this indicating light is on.
Water thermometer
It indicates the temperature of engine cooling water. Under normal
circumstances, the pointer is placed in a range of
284°
F
-
478°
F.
Attention: when the pointer is in red area, please immediately stop the
operation and reduce the engine speed to cool down till the pointer goes
back to white area.
Battery charge indicating light
It indicates the state of battery charge. This light will be on when the
start switch is placed in "ON" and will go out after the engine starts.
9
Attention: if the light keeps on or twinkling during the operation, it means
abnormal charge which needs an immediate check.
Hour meter
It records the traveling time of the
forklift
and is used as basis of
regular inspection and repair.
Engine oil pressure alarm light
It indicates the pressure condition of engine lubrication. This light will be
on when the start switch is placed in "ON" and will go out after the engine
starts. Attention: if the light keeps on or twinkling during the operation, it
means the engine oil pressure is less than
7
.2
5
psi which needs an
immediate check.
Horn button
The horn will blow when you push the horn button in the center of
steering wheel.
Key switch
OFF
OFF It is the place where the key inserts or is
pulled out. Here means the Forklift
stops.
ON The circuit is complete when the key
is in this place. The key will stay here
after starting the engine.
START the engine starts when the key is in
this place. The key will return back
to "ON" place when loosing
hand.
I Attention I
1. Do not put the key in "ON" place when the engine stops to avoid
battery discharging.
2. Do not turn the key to "START" place to avoid motor damage.
3. Do not keep the starting motor rotaring for more than 5 seconds
when starting the machine. Keep 120 seconds before start again.
4. Do not start the engine when the gear shift lever is not at the zero
gear.
10
Ranko R55 Forklift
Operator's Maintenance Manual
Operation &Use
Ranko R55 Forklift
Operator's Maintenance Manual
Operation &Use