Battery fails to
charge or the
charge current is
small
Excessive charge
current for a long
time
I.
2.
3.
4.
I.
2.
3.
Loose
anode
wiring
of
I. Block the electric Jock but do not
generator
start, and then there should be 12V
Loose battery wiring or circuit
voltage at the anode.
opemng
2. Visual inspection and tightening.
Loose drive belt
3. Visual inspection and tightening.
Damage of electronic regulator
4. Switch on the power but do not
start, and then there shall be 12V
voltage at the D+ end and the charge
indicator is on, if not, check the
exciting circuit. Check whether
there is 12V voltage at the B+ end,
if not, check if the wiring between
B+ end and battery
is
loosened.
Otherwise,
replace
the
voltage
regulator or generator.
Gravely insufficient voltage
1. Examine the B+ end of generator
Damage or short circuit of one
with
voltmeter
after
the
diesel
or two battery cells
engine is started. If the current is
Damage
or
short
circuit
of
excessive and the voltage is below
electrionic regulator
13.5V, the problem is on the battery.
2. Repair or replace the battery.
3. Reolace the regulator.
125
126
Ranko R55 Forklift
Operator's Maintenance Manual
Common Faults & Solutions
Ranko R55 Forklift
Operator's Maintenance Manual
Common Faults & Solutions