Two-port measurements with the tracking generator
R&S FSH
1145.5973.12 4.108
E-14
Selecting the marker format:
Press the MARKER MODE softkey.
Using the rotary knob or the cursor keys, select
MARKER FORMAT from the menu and confirm by
pressing either the MARKER FORMAT softkey or
the ENTER key.
A selection of different marker formats will appear:
•
dB MAG AND PHASE (RHO) outputs the
marker value for the reflection factor in
complex magnitude phase format, where the
magnitude is converted to dB.
•
LIN MAG AND PHASE (RHO) outputs the
marker value for the reflection factor in
complex magnitude phase format, where the
magnitude is linearly converted to a percent
value.
•
REAL AND IMAG (RHO) outputs the marker
value for the reflection factor in complex format
with real and imaginary components.
•
R+jX shows the marker value for the
impedance in complex format with real and
imaginary components. In addition, the
imaginary component of the impedance is
converted to inductance or capacitance and
displayed, with the marker frequency and sign
taken into account.
•
G+jB shows the marker value for the
admittance in complex format with real and
imaginary components. In addition, the
imaginary component of the admittance is
converted to inductance or capacitance and
displayed, with the marker frequency and sign
taken into account.
•
(R+jX/Z0) displays the marker value for the
standardized impedance in complex format
with real and imaginary components.
•
(G+jB/Z0) displays the marker value for the
standardized admittance in complex format
with real and imaginary components.
Using the rotary knob or the cursor keys, select the
marker format you need and confirm by pressing
either the MARKER MODE softkey or the ENTER
key.
Example: dB MAG AND PHASE (RHO)