R&S FSH3, R&S FSH6, R&S FSH18
Data Sheet
1145.5973.12
TI.11
E-14
Directional Power Sensor R&S FSH-Z44
Frequency range
200 MHz to 4 GHz
Power measurement range
30 mW to 300 W
VSWR referenced to 50
200 MHz to 3 GHz
3 GHz to 4 GHz
< 1.07
< 1.12
Power-handling capacity
depending on temperature
and matching
(see diagram below)
120 W to 1000 W
Insertion loss
200 MHz to 1.5 GHz
1.5 GHz to 4 GHz
< 0.06 dB
< 0.09 dB
Directivity
200 MHz to 3 GHz
3 GHz to 4 GHz
> 30 dB
> 26 dB
Average power
Power measurement range
CW, FM, PM, FSK, GMSK
3GPP W-CDMA,
cdmaOne, cdma2000,
DAB, DVB-T
Other modulated signals
CF: ratio of peak envelope
power to average power
30 mW to 300 W
30 mW to 120 W
30 mW to 300 W / CF
Measurement uncertainty
200 MHz to 300 MHz
300 MHz to 4 GHz
sine signal,
18 °C to 28 °C, no zero
offset
4.0 % of measured value (0.17 dB)
3.2 % of measured value (0.14 dB)