Operating Manual 1302.6163.12 - 03
6.137
R&S ESU
Remote Control – Description of Commands
INSTrument Subsystem
INSTrument:COUPle:PROTection
ALL | NONE
This command couples the RF protection attenuation of 10 dB for the analyzer and receiver modes
with one another.
To prevent damage to the RF input, activate this coupling.
Example:
"INST:COUP:PROT ALL"
Characteristics:
*RST value:ALL
SCPI:device-specific
Mode:
R, A
INSTrument:COUPle:SPAN
ALL | NONE
This command couples the start and stop frequencies of sweep and scan for the analyzer and receiver
modes with one another.
Example:
"INST:COUP:SPAN ALL"
Characteristics:
*RST value:NONE
SCPI:device-specific
Mode:
R, A