Programming Anit-Passback
Step
Example
Display
Action
1
Present an Editor key/card to the EK1000’s
internal reader.
2
SEL?
Press
INST/9
3
SetC
Press
4 times until P00 is displayed.
4
P00
or
P00
.
if Channel
Interlock is set.
Type a value,
0
-
60
(
0
to unset), followed by
SEL/SAVE
to confirm the change.
0
No pass back
1
Pass back with no forgiveness time limit.
2
-
60
Number of minutes after which a key/card
will work again if it is not used to leave the
area.
5
P15
(with an anti-
passback time
set to 15 mins)
As an example, a value of 15 sets Anti-Passback
with a forgiveness time of 15 minutes.
6
SEL?
Press
ESC
to leave Editor.
Manual Lock/Unlock for Controlling the Doors
It is possible to manually lock and unlock a door from the EK1000. It may be
necessary to do this, for instance, when a door needs to be kept unlocked while
contractors are working in an area, or equipment is being moved around. Also a
door that is normally open or a Time Profile may need to be locked while a
receptionist or guard is not available.
Doors controlled by a Time Profile
Manual lock will lock the door. The EK1000 requires users to present their
keys/cards to gain access when doors are locked. If you do not manually unlock
the door, the door will unlock again at its next automatic opening time according
to the Time Profile assigned.
If you manually unlock a door, and then do not manually lock the door, the door
will lock again at its next automatic closing time according to the Time Profile
assigned.
Doors not controlled by a Time Profile
Manual unlock will unlock the door and it will stay unlocked until manually locked
again.