74-07579-000-A 2/96
Page 30
© 1996 Radionics, Inc.
Using the Doors Function
Press
at any tine to move between Door 1 and Door 2.
Press
at any time to move between parameters. The parameters are
presented in the order described earlier in Door Options.
Press
ESC
at any time to return to
SEL?
Step
Example Display
Action
1
Present an Editor key/card to the EK1000’s
internal reader.
2
SEL?
Press
DOORS/6
.
3
d1Lt / 005
Lock Release Time for door 1.
Either: Type a new time,
0
-
255
, followed by
SEL/SAVE
to confirm the change, then press
to go to door 2,
or Press
to go to next parameter.
4
d1dt / 000
Door Open Time for door 1 used for the EK1000
Plus only.
Either:
Type a new time,
0
-
255
, followed by
SEL/SAVE
to confirm the change, then Press to go to
door 2
or Press
to go to next parameter.
5
d1tP / 0
Time Profile for door 1. Enter in the Time Profile
number
1
-
8
, if used, for automatically unlock and
locking the door. Set as
0
, for no auto unlock/lock
feature.
Either: Type a new Time Profile 0-8 followed by
SEL/SAVE
to confirm the change, then Press
to go to door 2,or Press to go to next
parameter.
6
d1oP /
IIIII
Door Options for door 1. See
Door Options
on
page 28 for full descriptions of each option.
Either: Press 1,2,3, or 5 to set or unset followed
by
SEL/SAVE
to confirm the change, then Press
to go to door 2,or Press to go to next
parameter.
7
d1UL / LoC
Manual Lock/Unlock for door 1. Used for
manually Locking and Unlocking doors 1 or 2.
See
Manual Lock/Unlock for Controlling the
Doors on page
32
section for full details of use.
Press
ESC
twice to leave Editor or repeat the
step 3-7 for entering the door parameters for
door 2.