Testing the Master Editor Key/Card and System
Present the new Master Editor
Key/Card. The display shows
SEL?
indicating that you are in the Editor
mode and may select one of the
functions .
When you install the Master Editor
Key/Card after clearing the
database, the EK1000 sets the
following default parameters
allowing you to immediately test the
system:
The EK1000 also installs the
Master Editor Key/Card as User
key/card 0001 with access through both doors and with no Time Profiles set (all
times and days).
Each door is given a Lock Release Time of five seconds.
Each lock is set to fail-secure (power to unlock).
If this is a new installation, Radionics recommends that the readers and
locks should be tested now.
If you were replacing the Maser Editor Key/Card and have preserved the existing
database, the new Master Editor Key/Card is the only change. The EK1000 still
gives complete access to the Master Editor Key/Card. The Master Editor
Key/Card normally loads into position 0001 replacing the old Master Editor ID
unless someone has loaded another key/card into position 0001. If so, the
EK1000 loads the Master Editor Key/Card into the next available position.
Figure 12: Entering the Editor