140
NO.
Parameter
Name
Setting Range
default
WRT
User
setting
f315
Output
terminal
function A of
T1
(T1A-T1B-
T1C)
28:ON=Local /OFF=Remote
30:Fault latch (Off at rtry)
32:Over torque:latch at fault
34:Under current :latch at
fault
36:Heavy fault
38:Light fault
40:Fault latch (With on retry)
42:All of are alarm
44:Over load 1 or 2 pre
alarm
46:PBr OH pre alarm
48:OT pre alarm
50:Alarm of cumulative time
52:Aarm of life time
54:Alarm of PTC thermistor
56:Status of MOFF signal
58:Status of brake
60:Motor
acceleration
process
62:Motor
deceleration
process
64:Motor
acceleration
or
deceleration process
66:Radiator
temperature
reaches
the
alarm
threshold
68:One
PLC
loop
is
complete
70:A PLC section speed is
complete
70~253
:
Not used
254
:
Always OFF
255
:
Always ON
40
●
f316
Output
terminal logic
selection of
LO-CLO
0
:
And logic
1
:
Or logic
0
●
f317
LO-CLO
output delay
0.0~60.0 s
0.0
○