124
No.
Communicati
on address
Description of function
Unit
Note
2
FD12
Real-time running frequency
0.01 Hz
3
FE18
Actual output frequency
0.01 Hz
4
FE09
DC bus input voltage
0.01 %
5
FE10
Output voltage
0.01 %
6
FE08
Output current
0.01 %
7
FE20
Output torque
0.01 %
8
FE29
Output power
0.01 kW
9
FE50
Motor speed (estimated)
1 rpm
10
FE11
Logic input
-
See A.15 for
details
11
FE12
Logic output
-
See A.16 for
details
12
FE30
Logic
input
AI1
(10-bit
accuracy)
-
Range
(0-
1023)
13
FE31
Logic
input
AI2
(10-bit
accuracy)
-
Range
(0-
1023)
14
FC39
Fault monitoring
-
See A.17 for
details
Table A.14 Real-time running state monitoring
Communication
address
Description of function
FD03
Real-time running state monitoring
Bit
Description
0
1
0
Reserved
-
-
1
Fault
No fault
Tripping
2-8
Reserved
-
-
9
Forward/reverse rotation
Forward
rotation
Reverse
rotation
10
Running/stop
Stop
Running
11-15
Reserved
-
-