QED Environmental Systems
AP-2 Manual
Page 6
This is How it Works
The AutoPump is a submersible compressed air-driven pump which fills and empties
automatically. It also controls the fluid level in a well automatically. The pump fills
(see
Figure 1)
when fluids enter either the top or bottom check valve. Air in the pump chamber
exits through the exhaust valve as the fluid fills the pump. The float inside the pump is carried
upwards by the fluid rising inside the casing until it pushes against a stop on the control rod,
forcing the valve mechanism to switch to the discharge mode.
The switching of the valve causes the exhaust valve to close and the air inlet valve to open.
This causes the pump to empty
(see Figure 1)
by allowing compressed air to enter the pump.
This pressure on the fluid closes the inlet check valve and forces the fluid up the discharge
tube and out of the pump through the outlet check valve. As the fluid level falls in the
pump, the float moves downwards until it pushes against the lower stop on the control rod,
forcing the valve mechanism to switch to the fill mode. The outlet check valve closes and
prevents discharged fluids from re-entering the pump. The filling and discharging of the pump
continues automatically.
Note
: The figures shown here are simplified
schematics.
Major AutoPump Features
•
The AutoPump System is small and lightweight and can be easily moved from site to site,
allowing quick response to changing conditions.
•
The hoses are color coded and all the fittings are different so only the proper connections
can be made.
•
Rugged construction ensures long system life, even under harsh conditions.
•
The entire system is pneumatically powered with no electrical components, thus avoiding
sparks in control power and sensing devices.
Summary of Contents for AutoPump AP-2
Page 15: ...Page 7 AP 2 Manual Revision 7 August 2007 Figure 1 How it Works Chapter 2 Overview 601345...
Page 22: ...QED Environmental Systems AP 2 Manual Page 14 Figure 3 Long and Short Bottom Loading AP 2 BL...
Page 32: ...QED Environmental Systems AP 2 Manual Page 24 Figure 7 Locking Quick Connects...
Page 34: ...QED Environmental Systems AP 2 Manual Page 26 Figure 9 AP 2 Assembly Well Cap with Holes...
Page 38: ...QED Environmental Systems AP 2 Manual Page 30 Figure 11 Examples of Well Caps...
Page 40: ...QED Environmental Systems AP 2 Manual Page 32 Figure 12 Hose Bundling Part 1 of 2...
Page 58: ...QED Environmental Systems AP 2 Manual Page 50 Figure 19 Exploded View of AP 2 Lever Assembly...
Page 109: ...Page 101 AP 2 Manual Revision 7 August 2007 Log Notes...
Page 110: ...Clean Environment Equipment AP 2 Manual Page 102...
Page 111: ...Page 103 AP 2 Manual Revision 7 August 2007 Log Notes...