Page 23
AP-2 Manual
Revision 7 - August, 2007
Compressed Air Supply
The AP-2 System includes a compressor-to-pump air line quick disconnect fitting for the
compressor.
There is a distinct air inlet on the AP-2; an “IN” is stamped next to it on the head of the
pump. The air inlet quick connect fitting on the pump has a female counterpart on the air
inlet hose. The air inlet must be connected for the AP-2 System to function. Do not lubricate
the compressed air coming out of the compressor. The AP-2 does not require lubrication and
excess oil may foul the filter/regulator.
WARNING:
The compressor should not provide more pressure than the filter can accept.
The metal bowl can accept 200 psi. Maximum output air pressure setting
on the standard regulator is 120 psi. A higher pressure regulator and gauge
are optional.
Component Assembly
Quick-Connects/Hose Barbs
Follow the instructions on
Figure 7
for properly securing the locking quick-connects. See
Figure 8
for properly securing hose barbs.
AutoPump Assembly
STEP 1 - Attach Fluid Discharge Hose (black)
Note:
If a well cap with holes is used, insert the hoses through the cap before
attaching hose.
a.
Attach the fluid discharge hose or tubing to the AutoPump.
(See Figure 9 and Figure 10)
b.
Attach the other end of the discharge hose to the fluid discharge point.
Chapter 4: Assembly & Installation
Summary of Contents for AutoPump AP-2
Page 15: ...Page 7 AP 2 Manual Revision 7 August 2007 Figure 1 How it Works Chapter 2 Overview 601345...
Page 22: ...QED Environmental Systems AP 2 Manual Page 14 Figure 3 Long and Short Bottom Loading AP 2 BL...
Page 32: ...QED Environmental Systems AP 2 Manual Page 24 Figure 7 Locking Quick Connects...
Page 34: ...QED Environmental Systems AP 2 Manual Page 26 Figure 9 AP 2 Assembly Well Cap with Holes...
Page 38: ...QED Environmental Systems AP 2 Manual Page 30 Figure 11 Examples of Well Caps...
Page 40: ...QED Environmental Systems AP 2 Manual Page 32 Figure 12 Hose Bundling Part 1 of 2...
Page 58: ...QED Environmental Systems AP 2 Manual Page 50 Figure 19 Exploded View of AP 2 Lever Assembly...
Page 109: ...Page 101 AP 2 Manual Revision 7 August 2007 Log Notes...
Page 110: ...Clean Environment Equipment AP 2 Manual Page 102...
Page 111: ...Page 103 AP 2 Manual Revision 7 August 2007 Log Notes...