QED Environmental Systems
AP-2 Manual
Page 60
These curves were derived from in-house tests using a pump with average air flow capacity.
Flow rates in the field may vary slightly due to temperature, air quality, flow restrictions and
minor differences in pump adjustments. Flow rates can be affected due to the natural cooling
effect of compressed air expansion. If this cooling effect is lowering the flow rate, decreasing
the air pressure to the pump can actually increase the flow rate in some cases. Another way
to reduce freezing of water vapor in compressed air is to use an air dryer on the compressed
air line.
The following charts show the performance flow rate curves for the Long and Short pumps.
Long Bottom and Top-Loading AP-2 AutoPumps
•
See Figures 20 and 21.
Short Bottom and Top-Loading AP-2 AutoPumps
•
See Figures 22 and 23.
The curves are categorized by pump type, hose size, depth of submergence and air supply
pressure. To determine the flow rate a pump will produce, the following information must
be known:
1. Pump
– Long, Short or Low Dardown; Top- or Bottom-Loading.
2. Discharge hose size
– 1/2 inch is standard. A larger inside diameter may yield a higher flow
rate. This depends on site conditions.
3. Fluid Inlet
Submergence – Select the submergence depth of the pump below the fluid
under normal operating conditions.
4. Air pressure
.
Appendix A: Performance Curves
Summary of Contents for AutoPump AP-2
Page 15: ...Page 7 AP 2 Manual Revision 7 August 2007 Figure 1 How it Works Chapter 2 Overview 601345...
Page 22: ...QED Environmental Systems AP 2 Manual Page 14 Figure 3 Long and Short Bottom Loading AP 2 BL...
Page 32: ...QED Environmental Systems AP 2 Manual Page 24 Figure 7 Locking Quick Connects...
Page 34: ...QED Environmental Systems AP 2 Manual Page 26 Figure 9 AP 2 Assembly Well Cap with Holes...
Page 38: ...QED Environmental Systems AP 2 Manual Page 30 Figure 11 Examples of Well Caps...
Page 40: ...QED Environmental Systems AP 2 Manual Page 32 Figure 12 Hose Bundling Part 1 of 2...
Page 58: ...QED Environmental Systems AP 2 Manual Page 50 Figure 19 Exploded View of AP 2 Lever Assembly...
Page 109: ...Page 101 AP 2 Manual Revision 7 August 2007 Log Notes...
Page 110: ...Clean Environment Equipment AP 2 Manual Page 102...
Page 111: ...Page 103 AP 2 Manual Revision 7 August 2007 Log Notes...