Page 93
AP-2 Manual
Appendix F: Pump Cycle Counter
Revision 7 - August, 2007
AP-2 Volumes Pumped Per Cycle
The volume of fluid pumped per cycle from an AutoPump® varies depending upon the inlet
air pressure and the total developed head (TDH) (static plus dynamic head). The closer the
pressures are to each other, (the TDH is almost the same as the inlet air pressure), the closer
the volume pumped per cycle will be to the lower end of the gallon range in the table below.
The TDH depends upon back pressure in the surface lines, hose size, fittings, vertical and
horizontal pumping distance, the number of pumps feeding the hose system, air pressure to the
pump, and the type of pump. The effects of some of these variables may cause the volume
pumped per cycle to vary from pump to pump on a single site.
Pump
Volume per Cycle: Range
Long AP2
0.14 - 0.17 gal (0.53 - .64 L)
Short AP2
0.05 - 0.08 gal (0.19 - 0.30 L)
AP2 AutoPump Models
Volume per Cycle: Typical
0.155 gal (0.59 L)
0.065 gal (0.25 L)
Summary of Contents for AutoPump AP-2
Page 15: ...Page 7 AP 2 Manual Revision 7 August 2007 Figure 1 How it Works Chapter 2 Overview 601345...
Page 22: ...QED Environmental Systems AP 2 Manual Page 14 Figure 3 Long and Short Bottom Loading AP 2 BL...
Page 32: ...QED Environmental Systems AP 2 Manual Page 24 Figure 7 Locking Quick Connects...
Page 34: ...QED Environmental Systems AP 2 Manual Page 26 Figure 9 AP 2 Assembly Well Cap with Holes...
Page 38: ...QED Environmental Systems AP 2 Manual Page 30 Figure 11 Examples of Well Caps...
Page 40: ...QED Environmental Systems AP 2 Manual Page 32 Figure 12 Hose Bundling Part 1 of 2...
Page 58: ...QED Environmental Systems AP 2 Manual Page 50 Figure 19 Exploded View of AP 2 Lever Assembly...
Page 109: ...Page 101 AP 2 Manual Revision 7 August 2007 Log Notes...
Page 110: ...Clean Environment Equipment AP 2 Manual Page 102...
Page 111: ...Page 103 AP 2 Manual Revision 7 August 2007 Log Notes...