Page 61
AP-2 Manual
Revision 7 – August, 2007
Appendix A: Performance Curves
Example:
A long Bottom-Loading AP-2 with a 1/2-inch discharge hose and 70 psi supply
pressure positioned 100 feet below ground and submerged 6 inches below the fluid will
produce about .77 gallons per minute (GPM).
The same pump submerged 10 feet below the fluid produces 1.0 GPM.
Note:
These flow rates are only applicable for the designated well head conditions.
Any additional resistance from out-of-well equipment (e.g. surface hoses,
valves, etc.) will affect the values
shown on these curves.
With the previous information, obtain the flow rate by using the following steps:
• On the horizontal scale, find the depth in the well at which the pump will be located.
• Trace that depth upwards to the line for the air inlet pressure you selected.
• Travel horizontally over to the vertical scale and read the flow rate.
Summary of Contents for AutoPump AP-2
Page 15: ...Page 7 AP 2 Manual Revision 7 August 2007 Figure 1 How it Works Chapter 2 Overview 601345...
Page 22: ...QED Environmental Systems AP 2 Manual Page 14 Figure 3 Long and Short Bottom Loading AP 2 BL...
Page 32: ...QED Environmental Systems AP 2 Manual Page 24 Figure 7 Locking Quick Connects...
Page 34: ...QED Environmental Systems AP 2 Manual Page 26 Figure 9 AP 2 Assembly Well Cap with Holes...
Page 38: ...QED Environmental Systems AP 2 Manual Page 30 Figure 11 Examples of Well Caps...
Page 40: ...QED Environmental Systems AP 2 Manual Page 32 Figure 12 Hose Bundling Part 1 of 2...
Page 58: ...QED Environmental Systems AP 2 Manual Page 50 Figure 19 Exploded View of AP 2 Lever Assembly...
Page 109: ...Page 101 AP 2 Manual Revision 7 August 2007 Log Notes...
Page 110: ...Clean Environment Equipment AP 2 Manual Page 102...
Page 111: ...Page 103 AP 2 Manual Revision 7 August 2007 Log Notes...