Page 57
AP-2 Manual
Revision 7 - August, 2007
Chapter 7: Troubleshooting & Repair
8. Fluid Check Valves
:
• Open the pump. Hold the pump vertically and pour water into the discharge check
valve. If water flows through, clean the valve.
• The valve assembly may be soaked in a solvent. Be careful to not damage the teflon
ball with the tools used for cleaning.
• Inspect the ball for wear. If it is too small to seal on the seat, or if it is obviously out
of round, replace the check valve.
• If the pump is a Bottom-Loading design, inspect the seat of the bottom check valve
for debris and wear. Clean or replace if necessary.
• If the pump is a Top-Loading design, remove the fluid inlet check valve, turn it upside
down, and pour water into it. If water flows through, clean it.
9.
Air Inlet Valve Timing
:
• Remove the pump casing. Connect the air supply. Push the control rod end of the
lever up to the head. Lower the rod slowly and stop at the point where the sound
of air drops dramatically.
• The levers should be nearly ±10 degrees parallel to the lower surface of the head
at this point.
• Check if the lever is jamming due to an improper adjustment.
Summary of Contents for AutoPump AP-2
Page 15: ...Page 7 AP 2 Manual Revision 7 August 2007 Figure 1 How it Works Chapter 2 Overview 601345...
Page 22: ...QED Environmental Systems AP 2 Manual Page 14 Figure 3 Long and Short Bottom Loading AP 2 BL...
Page 32: ...QED Environmental Systems AP 2 Manual Page 24 Figure 7 Locking Quick Connects...
Page 34: ...QED Environmental Systems AP 2 Manual Page 26 Figure 9 AP 2 Assembly Well Cap with Holes...
Page 38: ...QED Environmental Systems AP 2 Manual Page 30 Figure 11 Examples of Well Caps...
Page 40: ...QED Environmental Systems AP 2 Manual Page 32 Figure 12 Hose Bundling Part 1 of 2...
Page 58: ...QED Environmental Systems AP 2 Manual Page 50 Figure 19 Exploded View of AP 2 Lever Assembly...
Page 109: ...Page 101 AP 2 Manual Revision 7 August 2007 Log Notes...
Page 110: ...Clean Environment Equipment AP 2 Manual Page 102...
Page 111: ...Page 103 AP 2 Manual Revision 7 August 2007 Log Notes...