Page 85
AP-2 Manual
Appendix E: Air Compressor
Revision 7 - August, 2007
E. Oil leaks: check and tighten all bolts and nuts to manufacturer’s specifications. Replace
gaskets if necessary.
F. See “Overheating.”
III. Problem: Overheating
Solutions:
A. Pump running backwards: reverse rotation.
B. Inadequate ventilation or high ambient temperature: move intakes to outside and install
filters to protect against weather and foreign objects. Force air through enclosure if
necessary.
C. Restricted air intakes: clean or replace.
D. Loose or restricted valves: retighten, clean, or replace.
E. Incorrect installation: allow 18 inches minimum between wall and flywheel.
F. Insufficient air capacity: consult dealer. Seal all air leaks.
G. Insufficient oil: check level and consult dealer.
IV. Problem: Oil or Water in Air
Solutions:
A. Drain tank more often: use an automatic drain.
B. Reposition intake to take in cooler, drier air.
C. Install water dropouts with automatic drains in the air lines.
D. Install an after cooler prior to the air storage tanks.
Summary of Contents for AutoPump AP-2
Page 15: ...Page 7 AP 2 Manual Revision 7 August 2007 Figure 1 How it Works Chapter 2 Overview 601345...
Page 22: ...QED Environmental Systems AP 2 Manual Page 14 Figure 3 Long and Short Bottom Loading AP 2 BL...
Page 32: ...QED Environmental Systems AP 2 Manual Page 24 Figure 7 Locking Quick Connects...
Page 34: ...QED Environmental Systems AP 2 Manual Page 26 Figure 9 AP 2 Assembly Well Cap with Holes...
Page 38: ...QED Environmental Systems AP 2 Manual Page 30 Figure 11 Examples of Well Caps...
Page 40: ...QED Environmental Systems AP 2 Manual Page 32 Figure 12 Hose Bundling Part 1 of 2...
Page 58: ...QED Environmental Systems AP 2 Manual Page 50 Figure 19 Exploded View of AP 2 Lever Assembly...
Page 109: ...Page 101 AP 2 Manual Revision 7 August 2007 Log Notes...
Page 110: ...Clean Environment Equipment AP 2 Manual Page 102...
Page 111: ...Page 103 AP 2 Manual Revision 7 August 2007 Log Notes...