Configure the Module
6202-WA-DFNT-DFCM3
♦
ProLinx Gateway
Wireless EtherNet/IP to DF1 Master/Slave-3 ports
ProSoft Technology, Inc.
Page 49 of 190
February 2, 2009
Parameter Range
Description
Node Address 1 to 255
(255 =
broadcast)
This parameter specifies the slave node address on the network to
be considered. Values of 1 to 255 are permitted. If the value is set
to 255, the command will be a broadcast message on the network.
The DF1 protocol permits broadcast commands for write
operations. Do not use this node address for read operations.
Function Code
File Type
File Number
Elem #
Sub Elem #
See
Reference
section
These parameters specify the function to be executed by the
command. The Reference chapter in this Manual describes the
meaning of these values for each of the available supported
commands. Following is a complete list of the command supported
by the Master driver.
ProLinx Function Code Listing
Basic Command Set
Protected Write
Unprotected Read
Protected Bit Write
Unprotected Bit Write
Unprotected Write
PLC-5 Command Set
Word Range Write (Binary Address)
Word Range Read (Binary Address)
Read-Modify-Write (Binary Address)
Word Range Write (ASCII Address)
Word Range Read (ASCII Address)
Read-Modify-Write (ASCII Address)
SLC Command Set
Prot Typed Read with 2 addr fields
Prot Typed Read with 3 addr fields
Prot Typed Write with 2 addr fields
Prot Typed Write with 3 addr fields
Prot Typed Write with Mask 3 addr fields
2.5.12 [Data Map]
The [Data Map] section of the CFG file allows you to selectively copy data
registers, one register up to 100 registers at a time, from one internal database
area to another. Up to 200 entries can be made in the [Data Map] section,
providing a wide and powerful range of functionality.
You can use the Data Map section of the configuration file to copy data from the
device error or status table to the internal database register, or to copy data from
one area to another. The bytes and/or words copied can be altered to preset the
data (for example, floating-point data) in the correct format for a specific protocol.