Reference 6202-WA-DFNT-DFCM3
♦
ProLinx Gateway
Wireless EtherNet/IP to DF1 Master/Slave-3 ports
ProSoft Technology, Inc.
Page 151 of 190
February 2, 2009
The
Message Configuration
dialog box must be completed to define the data
set to be transferred from the processor to the module. An example of the dialog
box follows:
Complete the dialog box for the data area to be transferred. CIP Data Table
messages require a tag database element for both the source and destination.
The
Source Tag
is a tag defined in the ControlLogix Tag database. The
Destination Element
is the tag element in the DFNT module.
The module simulates a tag database as an array of elements defined by the
maximum register size for the module (user configuration parameter "Maximum
Register" in the [Module] section) with the tag name
int_data
.
In the previous example, the first element in the database is the starting location
for the write operation of ten elements. Additionally, the
Communication
information must also be configured. An example of the dialog box follows: