15-27
Redundancy (Switch 8212zl)
Displaying Management Information
Figure 15-19. Example of Show Redundancy Command for Standby Module
Show Flash
You can display the flash information on the standby module, as shown in
Figure 15-20. The Default Boot field displays which flash image will be used
for the next boot.
Figure 15-20. Example of Show Flash Command for Standby Module
Show Version
You can display the version information on the standby module, as shown in
Figure 15-21. The Boot Image field displays which flash image was last booted
from, even if the
boot set-default
command has been set to change the flash
Standby Console> show redundancy
Settings
--------
Mgmt Redundancy : Enabled
Statistics
----------
Failovers : 1
Last Failover : Mon Sep 26 09:50:40 2005
Slot Module Description Status SW Version Boot Image
---- ---------------------------------------- -------- ---------- ----------
1 ProCurve J9092A Management Module 8200zl Active K.12.XX Secondary
2 ProCurve J9092A Management Module 8200zl Standby K.12.XX Primary
1 ProCurve J9093A F1 Fabric Module 8200zl Enabled
2 ProCurve J9093A F2 Fabric Module 8200zl Enabled
The active management module was last booted from
secondary flash. The standby management module
was last booted from primary flash.
Standby Console> show flash
Image Size(Bytes) Date Version Build #
----- ---------- -------- ------- -------
Primary Image : 7493854 03/21/07 K.12.XX 1617
Secondary Image : 7463821 03/05/07 K.12.XX 351
Boot Rom Version: K.12.03
Default Boot : Primary
Will boot from primary flash
on the next boot.
3500-5400-6200-8200-MCG-Jan08-K_13_01.book Page 27 Monday, January 28, 2008 10:04 AM