14-22
Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
N o t e
The
retries
and
timeout
values are not used to send trap requests.
To verify the configuration of SNMPv2c informs, enter the
show snmp-server
command:
Figure 14-8. Display of SNMPv2c Inform Configuration
ProCurve Switch 5406zl(config)# show snmp-server
SNMP Communities
Community Name MIB View Write Access
---------------- -------- ------------
public Manager Unrestricted
Trap Receivers
Link-Change Traps Enabled on Ports [All] : All
...
Address Community Events Sent Notify Type Retry Timeout
--------------------- --------------- ----------- ----------- ----- --------
15.28.333.456 guest All inform 3 15
Excluded MIBs
Snmp Response Pdu Source-IP Information
Selection Policy : Default rfc1517
Trap Pdu Source-IP Information
Selection Policy : Configured IP
Ip Address : 10.10.10.10
SNMPv2c Inform
configuration
3500-5400-6200-8200-MCG-Jan08-K_13_01.book Page 22 Monday, January 28, 2008 10:04 AM