14-30
Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
To configure the switch to use a specified source IP address in generated trap
PDUs, enter the
snmp-server trap-source
command.
N o t e s
When you use the
snmp-server response-source
and
snmp-server trap-source
commands, note the following behavior:
■
The
snmp-server response-source
and
snmp-server trap-source
commands
configure the source IP address for IPv4 interfaces only.
■
You must manually configure the
snmp-server response-source
value if you
wish to change the default user-defined interface IP address that is used
as the source IP address in SNMP traps (RFC 1517).
■
The values configured with the
snmp-server response-source
and
snmp-
server trap-source
commands are applied globally to all interfaces that are
sending SNMP responses or SNMP trap PDUs.
■
Only the source IP address field in the IP header of the SNMP response
PDU can be changed.
■
Only the source IP address field in the IP header and the SNMPv1 Agent
Address field of the SNMP trap PDU can be changed.
To verify the configuration of the interface IP address used as the source IP
address in IP headers for SNMP replies and traps sent from the switch, enter
the
show snmp-server
command to display the SNMP policy configuration.
Syntax:
[no] snmp-server trap-source [<
ipv4-addr
> | loopback<0-7>]
Specifies the source IP address to be used for a trap PDU.
The
no
form of the command resets the switch to the default
behavior (compliant with rfc-1517).
Default: Use the interface IP address in generated trap PDUs.
<
ipv4-addr
>
:
User-defined interface IPv4 address that is used
as the source IP address in generated traps. IPv6 addresses
are not supported.
loopback <0-7>
: IP address configured for the specified
loopback interface that is used as the source IP address in a
generated trap PDU. If multiple loopback IP addresses are
configured, the lowest alphanumeric address is used.
3500-5400-6200-8200-MCG-Jan08-K_13_01.book Page 30 Monday, January 28, 2008 10:04 AM