EFX 885, 835, 825
Service Manual 20039-166
Page 99
©2011 Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Press the
GO
key to select.
This displays the installed version of upper boot software. The boot software is
used to upload new software into the upper display PCA.
The software part number will be displayed as XXXXX-XXX.
Press the
WORKOUTS/PROGRAMS
key to exit U-Boot Software.
U-Base
Software
Press the
key to go to U-Base
Software.
U-BASE SOFTWARE
will scroll across the display.
Press the
GO
key to select.
This displays the installed version of upper PCA software.
The software part number will be displayed as XXXXX-XXX.
Press the
WORKOUTS/PROGRAMS
key to exit the U-Base Software.
Lower
Software
Press the
key to go to Lower
Software.
LOWER SOFTWARE
will scroll across the display.
Press the
GO
key to select.
This
displays the installed version of lower PCA software.
The software part number will be displayed as XXXXX-XXX.
Press the
WORKOUTS/PROGRAMS
key to exit Lower Software.
Usage Log
Press the
key to go to Usage Log.
USAGE LOG
will scroll across the display.
Press the
GO
key to select.
Use the
,
keys to move through the list of programs. A message will scroll
describing the program, the number of times and the number of minutes the
program was used.
Press the
WORKOUTS/PROGRAMS
key to exit the Usage Log.
Error Log
Press the
key to go to Error Log.
ERROR LOG
will scroll across the display.
Press the
GO
key to select the test.
Use the
,
keys to move through the list of errors. The error messages will
list the error name, the odometer reading when the error occurred, the hour
meter when the error occurred and the drive motor current reading when the
error occurred.
The error log holds a maximum of 30 errors. If there is an error, this is where it
will be stored; otherwise, it should show
0 ERRORS.
When the error log has
stored the maximum recorded errors, any additional error will be logged as the
most resent and the oldest error will be erased from the log.
If you wish to clear the error log, press and hold the GO key for 5 seconds. The
message ERROR LOG CLEAR will be displayed.
Quick Error Log Access
- When in the Banner state the RESET key is pressed
for 5 seconds, the display will take you directly to the Error Log, if the Log has
Errors. If there are no errors,
STUCK KEY
is displayed on the STD, and then it
goes back to Banner state when the key is released.
Press the
RESET
key to exit to the
Banner.