EFX 885, 835, 825
Service Manual 20039-166
Page 95
©2011 Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Diagnostic Menus - Table
Test Type
Action
Description
Diagnostic
Software
At the Banner press
PAUSE/RESET,
ENTER, PROGRAMS, INPUT
DOWN
, INPUT UP
, ENTER,
INPUT DOWN
,
INPUT UP
, and
PROGRAMS
sequentially.
BEEPER TEST
will be displayed.
Beeper Test
Press the
GO
key to select the test.
The display will prompt the user to test the beeper sound.
Press the
GO
key to start the test.
This test will send an audible sound to the speaker mounted in the headphone jack.
Press the
ENTER
key to stop the test.
Press the
WORKOUTS/PROGRAMS
key to exit the beeper test.
Keyboard Test
Press the
key to go to the next test.
KEYBOARD TEST
will scroll across the display.
Press the
GO
key.
A representation of all of the keys on the console will be displayed. Pressing a
key on the console will cause the illuminated representation of that key to turn
off. Press all of the keys on the console to ensure that all of the keys are
functioning. The keyboard test will exit when all the keys have been pressed.
LCD Test
Press the
key to go to the next test.
LCD TEST
will scroll across the display
Press the
GO
key to select the test.
The unit will test all the different sections of LCD display screen then all sections
on, advancing through each section. Check the display to ensure that all LED
segments are illuminated.
Press the
WORKOUTS/PROGRAMS
key to exit the LCD test.
Heart Rate
Test
Press the
key to go to the next test.
HEART RATE TEST
will scroll across the display
Press the
GO
key to select the test.
Grasp both of the heart rate grips on the handlebar, after a couple of seconds the
heart rate will be displayed in the heart rate and smart rate displays.
Use chest strap transmitter or a wireless heart rate transmitter to test the
wireless heart rate function, after a couple of seconds the heart rate will be
displayed in the heart rate and smart rate displays.
Press the
WORKOUTS/PROGRAMS
key to exit the Heart Rate test.
Machine Test
Press the
key to go to the next test.
MACHINE TEST
will scroll across the display.
You may now proceed to the
BRAKE
test
, RPM
test
, BATTERY
test,
STRIDE POSITION
test, or
STRIDE
COUNT RESET
. Press the
,
key
until the desired test is displayed.
Press the
key to go to the next test.
BRAKE TEST
will scroll across the display.
Press the
GO
key to select the test.
The brake power bits information will be displayed
in the Distance Field. This
information is used to help diagnose problems with the Eddy Current Magnet.
Press the
WORKOUTS/PROGRAMS
key to exit the Brake test.
Press the
key to go to the next test.
RPM TEST
will scroll across the display.
Press the
GO
key to select the test.
Rotation count is determined by a zero crossing from one phase of the generator
and is represented as RPM in service mode. The count in service mode is real
time and should go to zero if you quit pedaling, which can help diagnose stride
count irregularities.
Press the
WORKOUTS/PROGRAMS
key to exit the RPM test.
Press the
key to go to the next test.
BATTERY TEST
will scroll across the display.
Summary of Contents for EFX 825
Page 15: ......