Procedure 10.10 Replacing the Input Step Up Pulley Assembly
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in Section One, Things You
Should Know.
1.
Remove the left and right side rear covers per Procedure 10.1.
2.
Remove the stairarm assemblies as described in Procedure 10.13.
3.
Remove the crankarm assemblies as described in Procedure 10.5
4.
Remove tension from the input pulley and generator belts as described below:
a.
Straighten the locking tabs and turn the left and right tension bolts counterclockwise until tension is
removed from the both belts. (Refer to Diagram 8.2.1)
b.
Remove both tension bolts and slide the input belt off of the step up pulley assembly.
5.
Place the input belt and step up belt in place on the replacement step up pulley. Set other
6.
Place the input belt and step up belt in place on the replacement step up pulley. Set other end of the
generator belt on the generator pulley.
7.
Replace the tension bolts and associated hardware removed in step 4b.
8.
Tension both belts per Procedure 8.2. Note the differences between tensioning a new belt and a existing
(used) belt.
9.
Replace the crankarms per Procedure 10.5.
10.
Replace the left and right side rear covers.