iNS/iDS 2-Wire System Manual
350-077
Rev. D - 1/20/2021
Page 8 of 107
Push button Operating Force Range: 1 to 3 lbs.
Maximum Audio Output Level: 100 dBA @ 1 meter
Dimensions W x D x H: 129 x 69 x 355 (mm - Reference Only)
Weight: 4.4 lbs.
Designed for Outdoor Use, Wet Location and Overvoltage Category: NEMA 250 4X
2.2
iCCU-S2 Intelligent Central Control Unit for Shelf
2.2.1
Technical Specifications
Input Voltage / Current: 110-220V, 50/60Hz, 3A
PBS Output: 24 VDC / 3.17A continuous, 3.75A surge
Ped Walk / Don’t Walk Inputs: Optically isolated 80 – 150 Volts AC/DC, 5mA max.
Ped Outputs: Optically Isolated 36 Volts AC/DC peak, 300mA Solid State Fused Contact Closure
General Purpose Inputs: 10
– 36 Volts AC/DC peak, 10mA max, Optically Isolated
EV Inputs: Active when pulled low (< 5 V to Logic Ground)
Communication: SDLC port, Ethernet, Wi-Fi (IEEE 802.11b/g/n)
*Operating Temperature Range: -34°C to +74°C, 95% Relative Humidity
*Storage Temperature Range: -40°C to + 85°C
Environmental Conditions:
• Mains supply voltage fluctuations up to ±10% of the nominal voltage
• Overvoltage Category ll
• Pollution Degree 2
Mounted inside all-weather enclosure, provided by customer
Dimensions W x D x H: 81 x 224 x 161
” (mm - Reference Only)
Weight: 3.28 lbs.
*The LCD temperature range is limited to -20°C to +70°C operational and -30°C to +80°C storage.