iNS/iDS 2-Wire System Manual
350-077
Rev. D - 1/20/2021
Page 104 of 107
17.4.5
Information Message
This option details what notice occurs when the button is held down for the extended push time. This typically allows for a
custom message that gives blind pedestrians additional information on the street they are crossing and its cross street.
The options noted as ‘with Pulse’ give a vibrotactile pulse at the beginning of a button push and a second pulse when the
button is held down for the extended push time.
The options noted as ‘no Pulse’ only have a vibrotactile pulse at the
beginning of the button push and only the sound will play at the extended push time.
The sound options are:
•
Tick: A click sound is heard. This is the same sound file that is configurable as Click in the Push Confirm Message
setting.
•
Custom: A special-ordered or programmed information message sound. If no custom sound has been loaded, then
the Custom option contains the click sound.
•
Direction:
“Traveling North” or whichever direction is selected for the Direction Message option will play.
•
Direction: The custom sound will play followed by “Traveling North” or whichever direction is selected for
the Direction Message option.
•
No Sound: No sound is played.
The available options are: Tick (no Pulse), Custom (with Pulse), Direction (with Pulse), Direction (with Pulse),
No Sound (with Pulse), Custom (no Pulse), Direction (no Pulse), Direction (no Pulse)
Factory Default: Tick (no Pulse)
17.4.6
Push Confirm Message
This function selects the sound played directly following a standard button push.
The available options are: Click, Wait, Custom, Custom 2
Factory Default: Wait
17.5
Other Settings
17.5.1
Button Push Force
This function adjusts the necessary force required on the button to place a call.
The available options are: Light, Medium, Firm
Factory Default: Medium
17.5.2
Cancel on Walk
This function gives the choice to immediately cancel or complete the information message when the intersection changes
to the Walk interval while playing the information message.
NOTE: It must be carefully examined before changing this option to
“No” since it can falsely shorten the Walk interval.
The available options are: No, Yes
Factory Default: Yes
17.5.3
Extended Push Time
This function adjusts the amount of time the button on the PBS has to be pressed and held before enabling the Extended
Push functions.