The next table shows the supplementary signals related to the camera interface (I
2
C, STROBE, SHUTTER, etc.)
which are also available at the expansion connector X5.
2.1.3.9.2 Secondary Camera Interface CSI2-B/CSI22 (X4)
The secondary camera interface (CSI2-B/CSI22 ) of the phyCORE-OMAP44xx is available at FFC connector X4
(Camera_2 interface of the phyCORE-OMAP44xx carrier board), which is compatible to PHYTEC's phyCAM-P
camera interface standard. It provides connectivity to an 8-bit parallel camera interface. The camera serializer
at U1 (SN65LVDS315RGER) converts the 8-bit parallel camera data to MIPI-CSI1 compliant serial data.
The serialized data is available on the differential serial data output DOUT which connects to the CSI2-B/CSI22
camera interface of the phyCORE-OMAP44xx.
The phyCAM-P camera interface provides also an I
2
C interface to control the image sensor of the camera module.
It connects to the I2C3 I
2
C bus of the phyCORE-OMAP44xx.
The supply voltage for the camera module ranges from 1.8 V to 3.3 V depending on the camera module attached
to the secondary camera interface. A step-down switching regulator at U29 adjusts the camera supply voltage
automatically according to the resistor connected to the camera module's "Power Voltage Set" output (input
CAM-2_VSET on camera connector X4). To attach the supply voltage to the Camera_2 interface circuitry jumper
JP1 must be closed.
Note:
Pins X1B5 to X1B8 on the phyCORE-Connector provide either signals of the keyboard interface, or camera
lanes 3 and 4 of the primary camera interface. The resistor array JN1 on the phyCORE-OMAP44xx allows to
choose which signals are brought out at these pins. In order to use lanes 3 and 4 of the primary camera
interface JN1 must be set to position 2. Please refer to
to see where JN1 is located.
Pin #
Signal Name
I/O
SL
Description
X5C10
CAM-1_SCL
I/O
VCC_CAM-1
Camera_1 I
2
C clock signal
1
1.
To use the Camera_1 I
2
C interface JP6 must be closed to have VCC_CAM_1 available.
X5C11
CAM-1_SDA
I/O
VCC_CAM-1
Camera_1 I
2
C data signal1
X5C13
CAM-1_CTRL1
-
-
Camera_1 control signal 1
X5C14
CAM-1_CTRL2
-
-
Camera_1 control signal 2
X5C15
X_CAM_STROBE
O
VCC_1V8_IO
Camera flash activation
trigger
X5C16
X_CAM_SHUTTER
O
VCC_1V8_IO
Mechanical shutter control
signal
X5C17
X_CAM_GLOBAL_RESET
I/O
1.8 V / VCC_1V8_IO
Camera sensor reset
Table 56:
CSI2-A/CSI21 Supplementary Signals at Expansion Connector X5
Note:
The function of camera control signals CAM-1_CTRL1 and CAM-1_CTRL2 depends on the camera board used.
Connector X2 allows to connect them either to GND, or VCC_CAM-1 (only available at X2 if jumper JP6 is closed)
or any other signal needed. Please refer to the hardware manual delivered with your camera board for precise