Part II: PCM-959/phyCORE-OMAP44xx Carrier Board
phyCORE-OMAP44xx
88
©
PHYTEC Messtechnik GmbH
2012
L-760e_1
2.1.2.4 Jumpers
The phyCORE Carrier Board comes pre-configured with 15 removable jumpers (JP) and 22 solder jumpers (J).
The jumpers allow the user flexibility of configuring a limited number of features for development purposes.
below lists the jumpers, their default positions, and their functions in each position.
the jumper pad numbering scheme for reference when altering jumper settings on the development board.
provides a detailed view of the phyCORE-OMAP44xx Carrier Board jumpers and their default settings.
In this diagrams a beveled edge indicates the location of pin 1.
Before making connections to peripheral connectors it is advisable to consult the applicable section in this
manual for setting the associated jumpers.
Figure 17:
Typical Jumper Numbering Scheme
provides a comprehensive list of all carrier board jumpers. The table only provides a concise summary
of jumper descriptions. For a detailed description of each jumper see the applicable chapter listed in the right
hand column of the table.
If manual modification of the solder jumpers is required please ensure that the board as well as surrounding
components and sockets remain undamaged while de-soldering. Overheating the board can cause the solder
pads to loosen, rendering the board inoperable. Carefully heat neighboring connections in pairs. After a few
alternations, components can be removed with the solder-iron tip. Alternatively, a hot air gun can be used to
heat and loosen the bonds.
Note:
Jumpers not listed should not be changed as they are installed with regard to the configuration of the
phyCORE-OMAP44xx.