phyCORE-i.MX35
24
PHYTEC Messtechnik GmbH 2010 L-734e_1
The jumpers (J = solder jumper) have the following functions:
Table 2:
Jumper settings
D
EFAULT
S
ETTING
A
LTERNATIVE
S
ETTING
S
EE
S
ECTION
J1
closed
EEPROM U2 is not write
protected
open
EEPROM U2 is write
protected
7.5.2
J2
closed
10k pull-down resistor to Dip-
Switch for boot select
X_BOOT2 (NOR/NAND)
open
X_BOOT2 is not connected
to Dip-Switch
J3
closed
10k pull-down resistor to Dip-
Switch for boot select
X_BOOT3 (MEM_TYPE[0])
open
X_BOOT3 is not connected
to DIP-Switch
J4
closed
10k pull-down resistor to Dip-
Switch for boot select
X_BOOT4 (MEM_TYPE[1])
open
X_BOOT4 is not connected
to DIP-Switch
6.1.2
J5
closed
Connects NFRB-signal from
the i.MX35x to R/#B2 pin of the
NAND-Flash
open
NFRB-signal from the
i.MX35x is not connected to
R/#B2 pin of the NAND-
Flash
J7
closed
Connects NFRB-signal from
the i.MX35x to R/#B1 pin of the
NAND-Flash
open
NFRB-signal from the
i.MX35x is not connected to
R/#B1 pin of the NAND-
Flash
J8
closed
Connects NFRB-signal from
the i.MX35x to R/#B3 pin of the
NAND-Flash
open
NFRB-signal from the
i.MX35x is not connected to
R/#B3 pin of the NAND-
Flash
J9
closed
Connects NFRB-signal from
the i.MX35x to R/#B pin of the
NAND-Flash
open
NFRB-signal from the
i.MX35x is not connected to
R/#B pin of the NAND-Flash
J10
closed
#CS1_3V3 is connected to
NANDF_CE3_3V3 to use
alternate function NF_CE3
open
#CS1_3V3 is not connected
to NANDF_CE3_3V3
J11
2 + 3
EEPROM A2 is connected to
GND (low)
1 + 2
EEPROM A2 is connected to
VDD_3V3 (high)
7.5.1
J12
closed
only 1 DDR bank populated,
CSD1 can be used as
CS3_3V3 connected to the
molex connector
open
2 DDR banks populated,
CSD1 is used for the 2nd
DDR bank, signal is not
connected to the molex
connector
J13
2 + 3
DS75 A2 is connected to GND
(low)
1 + 2
DS75 A2 is connected to
VDD_3V3 (high)
J14
2 + 3
EEPROM A1 is connected to
VDD_3V3 (high)
1 + 2
EEPROM A1 is connected to
GND (low)
J15
2 + 3
EEPROM A0 is connected to
GND (low)
1 + 2
EEPROM A0 is connected to
VDD_3V3 (high)
7.5.1
Summary of Contents for phyCORE-i.MX35
Page 51: ...CAN PHYTEC Messtechnik GmbH 2010 L 734e_1 43...
Page 55: ...JTAG Interface X2 PHYTEC Messtechnik GmbH 2010 L 734e_1 47...
Page 59: ...Hints for Handling PHYTEC Messtechnik GmbH 2010 L 734e_1 51...
Page 109: ...Revision History PHYTEC Messtechnik GmbH 2010 L 734e_1 101...
Page 115: ...Published by PHYTEC Messtechnik GmbH 2010 Ordering No L 734_1 Printed in Germany...