phyCORE-i.MX35
18
PHYTEC Messtechnik GmbH 2010 L-734e_1
P
IN
R
OW
X1D
P
IN
# S
IGNAL
I/O
SL
D
ESCRIPTION
1D
VIN
-
Power
Main Power Input (3.6 V - 5.5 V)
2D
VIN
-
Power
Main Power Input (3.6 V – 5.5 V)
3D
GND
-
0
Ground 0 V
4D
not connected
-
-
Pin left unconnected
5D #X_MASTER_RESET I
VDD_3V3
Master Reset Input/Reset button
6D
#X_RESET_MCU
O
VDD_3V3
Reset Output from reset unit
7D X_FUSE_VDD
-
FUSE_VDD
Fusebox write (program) Supply Voltage
(3.3 V)
8D X_TOUT
O
VDD_3V3
Open-Drain Thermostat Output of U3
(DS75)
9D
GND
-
0
Ground 0 V
10D
not connected
-
-
Pin left unconnected
11D
not connected
-
-
Pin left unconnected
12D
not connected
-
-
Pin left unconnected
13D
not connected
-
-
Pin left unconnected
14D
GND
-
0
Ground 0 V
15D
X_EN_VDD_3V3
I
VIN
Enable for 3.3 V power switch
16D
X_EN_VDD_1V8
I
VIN
Enable for 1.8 V power switch
17D
X_EN_VDD_1V375
I
VIN
Enable for 1.375 V power switch
18D
X_EN_LDO1_2
I
VIN
Enable for power-supply LDO (3.3 V,1.8 V)
19D
GND
-
0
Ground 0 V
20D
X_EN_VDD_ALIVE
I
VIN
Enable for VDD_ALIVE LDO (1.2 V)
21D
not connected
-
-
Pin left unconnected
22D
X_UART2_RXD
I
VDD_3V3
Serial Data receive line UART 2
23D
X_UART2_TXD
O
VDD_3V3
Serial Data transmit line UART 2
24D
GND
-
0
Ground 0 V
25D
X_UART2_RTS
I
VDD_3V3
Request to send UART 2
26D
X_UART2_CTS
O
VDD_3V3
Clear to send UART 2
27D
X_CAPTURE
I
VDD_3V3
Timer input capture
28D
X_COMPARE
O
VDD_3V3
Timer output compare
29D
GND
-
0
Ground 0 V
30D
X_CAN2_TX
O
VDD_3V3
CAN 2 transmit
31D
X_CAN2_RX
I
VDD_3V3
CAN 2 receive
32D
X_CAN1_TX
O
VDD_3V3
CAN 1 transmit
33D
X_CAN1_RX
I
VDD_3V3
CAN 1 receive
34D
GND
-
0
Ground 0 V
35D X
I/O
VDD_3V3
Receive positive input (normal)
Transmit positive output (reversed)
Summary of Contents for phyCORE-i.MX35
Page 51: ...CAN PHYTEC Messtechnik GmbH 2010 L 734e_1 43...
Page 55: ...JTAG Interface X2 PHYTEC Messtechnik GmbH 2010 L 734e_1 47...
Page 59: ...Hints for Handling PHYTEC Messtechnik GmbH 2010 L 734e_1 51...
Page 109: ...Revision History PHYTEC Messtechnik GmbH 2010 L 734e_1 101...
Page 115: ...Published by PHYTEC Messtechnik GmbH 2010 Ordering No L 734_1 Printed in Germany...