phyCORE-i.MX35
10
PHYTEC Messtechnik GmbH 2010 L-734e_1
33A #OE_3V3
O
VDD_3V3
Memory Output Enable
34A
LBA_3V3
O
VDD_3V3
Load Burst Address
35A BCLK_3V3
O
VDD_3V3
Burst
Clock
36A A2_3V3
O
VDD_3V3
Address-Line
A2
37A
GND
-
0
Ground 0 V
38A A4_3V3
O
VDD_3V3
Address-Line
A4
39A A5_3V3
O
VDD_3V3
Address-Line
A5
40A A7_3V3
O
VDD_3V3
Address-Line
A7
41A A10_3V3
O
VDD_3V3
Address-Line
A10
42A
GND
-
0
Ground 0 V
43A A12_3V3
O
VDD_3V3
Address-Line
A12
44A A13_3V3
O
VDD_3V3
Address-Line
A13
45A A15_3V3
O
VDD_3V3
Address-Line
A15
46A A18_3V3
O
VDD_3V3
Address-Line
A18
47A
GND
-
0
Ground 0 V
48A A20_3V3
O
VDD_3V3
Address-Line
A20
49A A21_3V3
O
VDD_3V3
Address-Line
A21
50A A23_3V3
O
VDD_3V3
Address-Line
A23
51A D0
I/O
VDD_3V3
Data_Bus
D0
52A
GND
-
0
Ground 0 V
53A D2
I/O
VDD_3V3
Data_Bus
D2
54A D3
I/O
VDD_3V3
Data_Bus
D3
55A D5
I/O
VDD_3V3
Data_Bus
D5
56A D8
I/O
VDD_3V3
Data_Bus
D8
57A
GND
-
0
Ground 0 V
58A D10
I/O
VDD_3V3
Data_Bus
D10
59A D11
I/O
VDD_3V3
Data_Bus
D11
60A D13
I/O
VDD_3V3
Data_Bus
D13
61A
VDD_1V8
-
VDD_1V8
1.8V supply voltage
62A
GND
-
0
Ground 0 V
63A
not connected
-
-
Pin left unconnected
64A
not connected
-
-
Pin left unconnected
65A
not connected
-
-
Pin left unconnected
66A
not connected
-
-
Pin left unconnected
67A
GND
-
0
Ground 0 V
68A
not connected
-
Pin left unconnected
69A
X_FEC_TDATA3
O
VDD_3V3
Fast Ethernet Transmit Data 3
70A X_FEC_RX_ER
R
I
VDD_3V3
Fast Ethernet Receive Data Error
71A X_FEC_RDATA2 I
VDD_3V3
Fast Ethernet Receive Data 2
72A
GND
-
0
Ground 0 V
Summary of Contents for phyCORE-i.MX35
Page 51: ...CAN PHYTEC Messtechnik GmbH 2010 L 734e_1 43...
Page 55: ...JTAG Interface X2 PHYTEC Messtechnik GmbH 2010 L 734e_1 47...
Page 59: ...Hints for Handling PHYTEC Messtechnik GmbH 2010 L 734e_1 51...
Page 109: ...Revision History PHYTEC Messtechnik GmbH 2010 L 734e_1 101...
Page 115: ...Published by PHYTEC Messtechnik GmbH 2010 Ordering No L 734_1 Printed in Germany...