22 Troubleshooting / fault elimination
Observe the safety instructions!
This work must only be carried out by appropriately trained personnel!
In case of overload or a fault occurring,
one of the fuses,
F1 to F4
, at the junction
box will be tripped.
To change the blown fuse:
•
Pull the machine’s power plug and
unplug any connected loads!
•
Use a screwdriver to unscrew the fuse
terminal F1 to F4 on and remove the fuse.
Replace any blown fuses with equivalent
fuses only. (Ratings are listed later on in
the manual.)
•
Check the cables for visible damage.
•
Have defective cables immediately
replaced by suitable new cables.
The main and emergency stop switches can
only be turned on if 230 V voltage is available
at the controller.
If the fault persists, contact the system
manufacturer.
Fuses
F1 to F4
Fuse
F1
Control fuse 2 A T 230 Volt
Fuse
F3
Display Y transverse axis 400 mA 24 Volt
Fuse
F4
Display Y longitudinal axis 400 mA 24 Volt
Fuses: Standard glass tube fuses 230 V 5 x 20 mm