Safety – Setting up and commissioning – Operation – Spare parts lists
Positioning laser (optional)
2021-03-22
15
7 Positioning laser (optional)
Laser Class 1 as per DIN EN 60825-1:2008-05, = 650 nm, 5 mW
8 Operating conditions
The electrical equipment is only suitable for operation in dry conditions and at ambient temperatures
of -10 °C to 50 °C. Operating under any other conditions is not permissible!
9 Sound power level L
WA
Saw unit (manufacturer’s specification)
97.9 dB(A)
Milling cutter unit (manufacturer’s specification)
99.0 dB(A)
Groove sawing unit (manufacturer’s specification)
92.8 dB(A)
10 Pneumatic power unit lifting system
This machine is supplied with a pneumatic power unit lifting system. A pressure regulator installed in the
machine to regulate the air pressure to 5 bar. The compressor used must be capable of building up at least
7 bar pressure. The hose must withstand a pressure of at least 10 bar (must be certified). (suitable
compressors and pressure hoses are available from PFT)
11 Workpiece
Material
Gypsum boards, gypsum fibre, cement fibre and hard plasterboard, fibreboard,
chipboard, soft fibreboards, aluminium composite materials and plastic boards.
11.1 BOARDMASTER 2500
Maximum operational load
150 kg
Maximum board size
2500 mm x 1260 mm
Maximum plate thickness 2500 mm x 1260 mm
48 mm