2/2
B 25
Filling the machine oil housings
G 03888 - Edition 03 - August 12
1
2
3
4
5
6
8
9
Filling of the Roots motor
side housing
Filling procedure
Make sure the pump is off
(main switch to “0” position)
and
positioned horizontally,
then remove the pump covers.
Use the funnel equipped with a flexible tube delivered with the
pump.
Remove the grid located on the top cover to access to the fill
plug easier. Remove the fill plug (
1
). Position the funnel in the oil
fill neck. Fill the pump with oil according to the recommended
quantities.
Do not exceed the indicated quantities.
The oil level should be
in the middle of the sight glass (
2
). For this to be accurate, wait a
few minutes for the oil to settle over all internal surfaces.
Replace the fill plug securely.
Remove the fill plug (
7
). Position the funnel equipped with flexible
tube in the oil filler neck. Fill the pump with oil according to the
recommended quantities.
Do not exceed the indicated quantities.
The oil level should be
in the middle of the sight glass (
8
). For this to be accurate, wait a
few minutes for the oil to settle over all the internal surfaces.
Replace the fill plug securely.
Ensure that the oil level of the pump is correct.
Filling of the Roots gears
side housing
(except Roots on A803H)
1
- Roots motor side housing fill plug
2
- Roots motor side housing sight glass
3
- Roots motor side housing drain plug
4
- FB203 fill plug
5
- FB203 sight glass
6
- FB203 drain plug
7
- Roots gears side housing fill plug
8
- Roots gears side housing sight glass
9
- Roots gears side housing drain plug
Roots
FB203
Check that the oil level is in the
middle of the sight glass.
Oil level check on Roots
Correct oil level
adixen Vacuum Products - A3H Series Operating instructions