G 03905 - Edition 03 - February 10
1/2
C 44
Saving and loading of pump
configuration (with HHR)
At pump installation or replacement, it may be interesting to copy
the configuration (set of all the parameters and operation setting
programmed by the user) from a pump to another.
The pump configuration is memorized in the internal electronics
of monitoring.
Enter in the menu by
SET
.
Go on using
+
to access
the MANAGEMENT menu
and valid by
ENTER
.
Go on using
+
to access
the CONFIG.SAVE menu
and valid by
ENTER
.
The following screen appears:
Validate with
ENTER
button.
The pump configuration is then
duplicate into the HHR memory.
Return to main menu and exit the setting mode by
SET
.
Disconnect the hand-held remote.
Configuration saving
STORAGE
>>>CONFIG SAVE<<<
CONFIG. LOAD
Loading and saving the parameters with the pump in operation may result
in a software conflict.
Perform these operations when the pump is switched on but with pumping
stopped.
MAINTENANCE
>>>MANAGEMENT<<<
OPERATING TIME
LAST ACTIONS
CONFIG SAVE
CONFIRM ?
adixen Vacuum Products - A3H Series Operating instructions