2/2
D 400
Pump or Roots does not start
G 03915 - Edition 02 - July 10
Incident
Cause
Troubleshooting
HHR is showing
Hand-held remote is on soft
loading configuration
Set the switch
S1
to “OFF”
(
D 10
).
Switch OFF for 10s, then switch
“ON” again.
Check the connection.
•
•
•
Other problem
Call customer service center.
HHR is showing
No communication between M4
and HHR
Check the connection.
•
Electronic is in “slave” mode:
without hand-held remote
controls
Set the coding wheel
S2
to “OFF”
position (
D 10
).
Stay OFF for 10s, then set to “ON”
position again.
•
•
Other problem
Call customer service center.
HHR is showing
… by pressing on any key …
Pump is used with several HHR
Only one HHR can monitor the
pump.
•
Press on
CONTROL
to disable the
monitoring on other HHR displays.
•
Press on
CONTROL
on the
requested HHR to monitor the
group.
•
Wait for the display:
•
Other problem
Call customer service center.
HHR is showing
Pump in storage mode
Set the main switch to
“0”
to
switch off the pump.
Switch it on again.
•
•
HHR is showing
In Remote mode: no cover plug or
bad connection
Check the wiring of
J14
connector
(
B 70
).
•
Other problem
Call customer service center.
Only Functioanl Block starts
No “Roots” message on the
display
Incorrect M4 configuration
Configure “Roots CMD” on
Enabled
•
Roots CMD Enabled
Press “ROOTS” key
•
ALCATEL-AVTF
MONITORING V2.0F
PRESS ENTER
OR AUTO-CONNECTION
ALCATEL-AVTF
MONITORING V2.0F
PRESS ENTER
OR AUTO-CONNECTION
Wait ???
Wait ???
XXH LOC. N2 ROOTS
PUMPING STOPPED
MM/DD/YY HH:MM
XXH LOC. N2 ROOTS
PUMPING STOPPED
MM/DD/YY HH:MM
XXH LOC. N2 ROOTS
COMMAND NOT ALLOWED
MM/DD/YY HH:MM
XXH LOC. N2 ROOTS
COMMAND NOT ALLOWED
MM/DD/YY HH:MM
XXH LOC. N2 ROOTS
PUMPING STOPPED
MM/DD/YY HH:MM
XXH LOC. N2 ROOTS
PUMPING STOPPED
MM/DD/YY HH:MM
STOCK
STOCK
REM
REM
HHR doesn’t work or displays a message
adixen Vacuum Products - A3H Series Operating instructions