10.2.1 Connection Via Relays
We recommend control via relays - see circuit diagram.
24 V
GND
weiß / white (1)
grau / grey (5)
rosa / pink (6)
gelb / yellow (4)
grün / green (3)
braun / brown (2)
blau / blue (7)
rot / red (8)
Fig. 10-3: Circuit diagram for connection via relays
K1:
Control input from control cabinet via voltage free contact
K2:
Error signal (active low)
K3:
Filling level signal (active low)
K4:
Input to impulse control from control cabinet via voltage-
free contact (additional discharge)
10.2.2 Direct Connection to PLC
(Programmable Logic Controller)
GND
+24 V
In 1
In 2
Out 1
Out 2
GND
+24 V
gelb / yellow (4)
grau / grey (5)
rosa / pink (6)
braun / brown (2)
blau / blue (7)
PLC
rot / red (8)
Fig. 10-4: Circuit diagram for direct connection to a PLC
• Connection to terminal “GND” is imperative for direct connection
to a PLC (Fig. 10-4)!
• For 24 V DC, the mains supply (plug connection A) MUST NOT be used!
• The used 24 V power supply must be sufficiently dimensioned for
the operation of perma ECOSY acc. to its power consumption
(chapter 3.1.2.).