© 2020 - perma-tec
GmbH & Co. KG
|
www.perma-tec.com
|
15
14
|
perma ECOSY
WARNING
3.2
Operating Conditions
The following restrictions must be observed for safe operation
of the lubrication system and its connections:
• The lubrication system must not be placed, mounted and /
or operated in an oxygen-enriched environment! - Explosion
hazard!
• Oxygen cylinders or storage tanks with liquid or gaseous
oxygen inside must not remain or be placed inside safety
clearance zone (refer to corresponding safety data sheets)!
• DO NOT mount the lubrication system on surfaces where
the temperature may exceed the permissible operating
temperature of the lubrication system!
• DO NOT mount the system in places where hot gases or hot
fluids may leak from pipes or tubes and may blow or flow
against the lubrication system!
• Prior to any welding, the lubrication system must be removed
from the area where temperatures may rise. Pipes or tubes
containing lubricants must be removed from the danger area
and, if necessary, they should be emptied!
• Prior to doing work where glowing metal parts or liquid
metal drops may reach the lubrication system and/or its
plastic tubes, protect any parts that could be reached and
damaged by these heat sources!
• Prior to doing work where arcs might occure, protect any
endangered tubes and ECOSY 5 parts!
3.2.1 Temperatures
• Range: -20 °C to +60 °C (-4 °F to +140 °F) with suitable oils.
• Within this temperature range and with a constant temperature,
a precise discharge and a pressure build-up of up to 10 bar max.
are guaranteed.
• If extreme temperatures exist (above +60 °C / +140 °F and
below -20 °C / -4 °F), correct operation cannot be guaranteed.
The system also has the option for the user to select and pro-
gram a temperature limit. If the temperature falls below this
selected limit, the system is shut down to prevent damage.