perma ECOSY
NOTE
CAUTION
6
Operation
6.1
Preparation
Before starting perma ECOSY 5 for the first time, fill the reservoir
until the display no longer shows “RESERVE” (see chapter 7).
If there is not enough space to refill the reservoir using a container,
use a pump (with filter) and a clean tube.
PRIOR to operating the lubrication system, all lubrication points
and connection tubes/pipes must be sufficiently prefilled with the
same lubricant that the perma ECOSY 5 contains!
In case of short connection tubes or pipes, the test function can be
used for this purpose (see chapter 8.5 “Carrying Out a Test Run”).
For longer tubes or pipes (longer than 2 m), an external pump is
recommended (it takes about 12.6 cm
3
of oil to fill 1 meter of
tubing).
6.2
First Start and Operation
• perma ECOSY 5 comes with a standard factory set discharge of
0 ml/1000 h (basic setting).
• Setting of the desired discharge can be done in increments of 1.
Possible settings are 0 (outlet inactive) up to 9999 ml/1000 h.
•
Do not exceed the max. pump capacity of 50 l (13.21 US gallons)
per year for all outlets combined.
Before operation, users must determine and set the correct
discharge for their application (see chapter 8.3.1 “Setting the
Discharge Amount”)!
• Start the discharge by setting the desired operating mode
(Configuration Operating mode TIME, CONTROL or SENSOR),
see chapter 8.4.2 “Setting of Operating Mode”. Depending on the
selected operating mode (CONTROL or SENSOR), an external
signal must exist.
• Use the test function (chapter 8.5.2 “Test Run for All Outlets”) to
ensure that every activated outlet has been recognized by the
system and will discharge according to the desired setting.
CAUTION
CAUTION